AC Redundant Module 1100 watts
YM-2112AAR
FEATURES
  • •321.5 (L) x 54.5 (W) x 40.0 (H) mm
  • •N+1 Redundant
  • •Support PMBus 1.2
  • •Hight Power Density 25.72 W/in3
  • •Application for IPC/Storage/Embedded server/Networking
INPUT
Input Voltage90 - 264VAC
Input Frequency47-63Hz
Input Current7.5A max at 240VAC
Inrush Current55A max at 264VAC
Power Factor0.93 at 115VAC / 60Hz,0.90 at 230V / 50Hz
Earth Leakage Current3.5mA max at 264VAC / 50Hz
 
 
GENERAL
Efficiency80 Plus PLATINUM certified,Highest efficiency 94% at 230VAC
Power Density25.72 W/in³
MTBF100 kHrs per Bellcore SR-332 ISSUE1 at 25°C ambient
 
 
 
 
 
ENVIRONMENTAL
Operating Temperature0 to 50°C
Operating Humidity85% RH, Non-condensing
Storage Temperature-40°C to +70 °C
Operating AltitudeSea level to 5,000 M
Shock Operating5G, no malfunction
Non-Operating0.02G²/Hz form 20Hz to 1kHz
Vibration Operating0.01G²/Hz at 10Hz, 0.02G²/Hz at 20Hz
 
EMC & SAFETY
EmissionsEN55022, class A Conducted EN55022, class A Radiated
Harmonic CurrentsEN61000-3-2
Voltage FlickerEN61000-3-3
EFT/BurstEN61000-4-4
SurgeEN61000-4-5
Conducted ImmunityEN61000-4-6
Safety ApprovalsUL/cUL, TUV, CB, CE, CCC, FCC
 
OutputMinimum LoadMaximum LoadConditionRipple & Noise
+12V 1.0A 90.2A 150mV p-p
+5VSB0.1A3.6A60mV p-p